Mica Tape
Phlogopite Mica
Tape consist of the high quality phlogopite mica paper bonded to an glass fiber
cloth as the supporting fabric, impregnated with a specially selected high
temperature resistant silicon resin. Calcined mica tape is made of calcined
muscovite mica, it updated the high temperaturer above 1000 degree. For the
excellent high voltage and temperature characteristics, it has been widely used
for fire resistant cable, which has high safe demand machine and place, like:
Aerospace field, Safe work tunnel, Motor and electric equipment cables,
signaling cables, especially high-voltage cable and so on. Electrical
insulation mica tape for cable is a result of compounding process between
phlogopite or synthetic mica and glass fiber cloth or PE film, with its
adhesive being silicon resin, which is mainly used as refractory thermal
insulation between core wire of fire-resistant cable and casing. It is used as
the main flame resistant insulating layer of various flame resistant cables.
The silicone resin binder in this tape we select is outstanding and there's no
harmful smoke when it burns.
Place of Origin: Shanghai,
China (Mainland)
Brand Name: Shenglongpan
Model Number: Synthetic Mica tape
Type: Insulation Tape
Material: mica PET
Application: High Temperature, Low Voltage
Rated Voltage: Dielectric strength> 18KV/mm
Tensile Strength: Flexural strength≥16 kgf/mm2
Density g/cm3: 1.7-2.35
Feature: No delaminated saw-teeth
Brand Name: Shenglongpan
Model Number: Synthetic Mica tape
Type: Insulation Tape
Material: mica PET
Application: High Temperature, Low Voltage
Rated Voltage: Dielectric strength> 18KV/mm
Tensile Strength: Flexural strength≥16 kgf/mm2
Density g/cm3: 1.7-2.35
Feature: No delaminated saw-teeth
Quick Details
a. Place of Origin: Shanghai,
China (Mainland)
b. Brand Name: Shenglongpan
c. Model Number: Synthetic Mica
tape
d. Type: Insulation Tape,
Insulation Tape, single glass synthetic mica tape
e. Material: mica PET
f. Application: High
Temperature, Low Voltage
g. Rated Voltage: Dielectric
strength> 18KV/mm
h. Tensile Strength: Flexural
strength≥16 kgf/mm2
i. Density g/cm3: 1.7-2.35
j. Feature: No delaminated
saw-teeth; no burs; smooth edges
k. Strong points: flexible, rigid,
thick, insulating
l. Temperature: 500℃ & 800°C
m. Color: white, silver, grey
n. mica content: ≥90%
o. THICKNESS: 0.08mm-0.15mm
p. Width: 3mm-1000mm
q. Length: 500m-30000m
r. Outer Diameter: 100mm-1000mm
s. Inside Diameter: 50mm-150mm
Packaging & Delivery
Packaging
Details:
|
standard
exporting packing or follow clients' demand
|
Delivery
Detail:
|
15-20
days after receiving order
|
Mica Tape
Mica tape is widely used to
withstand/ resist fire cable. which adopt high-quality Phlogopite mica papers,
fiber-glass clothes or PE films as their reinforcing materials, and also with
organic silicon resin as its adhesive, then are baked with high temperature, and
compressed. They can withstand temperature up to 1000 °C for 3 hrs.
Relative data
Thickness
:
|
0.125±0.015mm
|
Width
:
|
12
mm
|
Inner
Dia. :
|
76
mm
|
Outer
Dia. :
|
395/15mm
|
Length
|
1000M
|
Total
substance (g/m2)
|
170±10
|
Mica
content (g/m2)
|
120±5
|
Glass
content (g/m2)
|
32±2
|
Bond
content (g/m2)
|
18±3
|
Dielectric
constant(kv/layer)
|
>1.2
|
Tensile
strength (N/cm)
|
>120
|
Thermal
Conductivity (W/mC)
|
0.2-0.25
|
Advantage feature
1. Strong adhesion.
2. High tensile strength.
3. Protecting the surface from rust,
humidity, water.
Application
1. Fire resistance cable.
2. High temperature resistance
cable.
3. Fire-fighting equipment and
emergency lights.
4. Other emergency facilities
wizard power and control cable.
Relative data
Item
|
Unit
|
80μm
|
100μm
|
110μm
|
120μm
|
130μm
|
140μm
|
150μm
|
Apprearance
|
|
No alien material, no split, scar &
hole, no broken folded
|
||||||
Length
|
m
|
500/1000/2000
|
||||||
Thickness
|
mm
|
0.08±0.015
|
0.10±0.015
|
0.11±0.015
|
0.12±0.015
|
0.13±0.015
|
0.14±0.015
|
0.15±0.015
|
Weight
|
g/m2
|
105±10
|
130±10
|
145±10
|
170±15
|
180±15
|
215±15
|
225±15
|
Mica
Content
|
%
|
>55
|
>60
|
>63
|
>65
|
>70
|
>70
|
>70
|
Breakdown
Voltage
|
KV
|
>1.0
|
>1.1
|
>1.3
|
>1.5
|
>1.7
|
>1.8
|
>2.0
|
Tensile
Strength
|
N/15mm
|
≥150
|
≥160
|
≥180
|
≥200
|
≥200
|
≥200
|
≥200
|
Binder
Content
|
%
|
13±3
|
13±3
|
13±3
|
13±3
|
13±3
|
13±3
|
13±3
|
Fire
Grade
|
℃
|
750℃ - 800℃
|